Home Our Products Software United DATUM Software | |
|
|
|
|
  : The LE-30CTA includes specialized functions like weak excitation (improves torque at low speeds) and automatic polarity judgment , which ignores wiring specifications (compression vs. tension) to simplify setup.
: Some versions support an operation memory cassette, allowing you to transfer data between different controllers easily. Installation and Safety Guidelines
: Keep the control (weak electric) wiring separate from the main power (strong electric) lines to avoid signal interference. How to Access the Manual
According to the Mitsubishi Electric User Manuals , several critical safety steps must be followed:
The is a high-precision automatic control device designed for winding and unwinding applications in industries such as printing, plastic film, and electrical wiring. It functions as a feedback system, receiving signals from tension detectors (like the LX-TD series) to maintain consistent material tension. Core Specifications Power Supply AC 100~240V Rated Output DC 12~24V (0~24V for clutches/brakes) Torque Command 0~5V for AC servo amplifiers I/O Points 32 mixed input/output points Display Multi-language LCD (English, Japanese, Chinese) Counting Speed Maximum 200k pulse/s Key Features & Functionality
: You must perform solid grounding (Class D or better, 100 Ωcap omega or less) to ensure the safety of the operator and the unit. |
| | |
|
|
| | | |